We have been also concentrating on enhancing the things management and QC method so that we could preserve terrific edge inside the fiercely-competitive enterprise for Water Filter Replacement Filter , Uf In Filter , Water Filter Replacement Filter , We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
Manufactur standard Membrane Treatment - UF Membrane Module PVC Ultrafiltration Membrane Module UFc4040 RO housing – Bangmo Detail:
Applications
Production of mineral water, spring water, or other sterile liquid.
Drinking treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service?conditions of different water sources:
Ingredient |
Effect |
SS, Particles?> 1μm |
Removal Rate?≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
>?4 log |
Turbidity |
<0. 1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 15NTU. This product is qualified for drinking water related products.
Product Parameters
![product-description1](https://ecdn6.globalso.com/upload/p/2605/source/2024-10/670cd4a77382b33968.jpg)
Technical Parameters
Filtering?Type |
Inside-out |
Membrane?Material |
Modified?PVC |
MWCO |
100K Dalton |
Membrane?Area |
3.8m2 |
Membrane?ID/OD |
1.0mm/1.8mm |
Dimensions |
Φ90mm*1016mm |
Connector?Size |
Φ19mm |
Application Data
Pure?Water?Flux |
1,200L/H?(0.15MPa, 25C) |
Designed?Flux |
35-100L/m2.hr?(0.15MPa, 25C) |
Suggested?Working?Pressure |
≤ 0.2MPa |
Maximum?Transmembrane?Pressure |
0.2MPa |
Maximum?Working?Temperature |
45C |
PH?Range |
Working: 4-10; Washing: 2-12 |
Operating?Mode |
Cross-flow?or?Dead-end |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused?by large particles in raw water.
Turbidity |
≤ 15NTU |
Oil?&?Grease |
≤?2mg/L |
SS |
≤ 20mg/L |
Total?Iron |
≤?1mg/L |
Continuous?Residual?Chlorine |
≤?5ppm |
COD |
Suggested?≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Maximum?Backwashing?Pressure |
0.2MPa |
Backwashing?Flow?Rate |
100-150L/m2.hr |
Backwashing?Frequency |
Every?30-60min. |
Backwashing?Duration |
30-60s |
CEB?Frequency |
0-4?times per day |
CEB?Duration |
5-10min. |
CIP?Frequency |
Every 1-3 months |
Washing?Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic?Pollution?Washing |
0.2%?Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic?Pollution?Washing |
1-2% Citric?Acid/0.2% Hydrochloric?Acid |
Component Material
Component |
Material |
Membrane |
Modified?PVC |
Sealing |
Epoxy?Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
Our products are broadly regarded and reliable by end users and can meet up with constantly transforming financial and social requires of Manufactur standard Membrane Treatment - UF Membrane Module PVC Ultrafiltration Membrane Module UFc4040 RO housing – Bangmo , The product will supply to all over the world, such as: Indonesia, Liberia, Tunisia, Hard work to keep making progress, innovation in the industry, make every effort to high quality enterprise. We try our to build the scientific management model, to learn abundant experienced knowledge, to develop advanced production equipment and production process , to create the first-call quality goods, reasonable price , high quality of service , quick delivery , to present you create new value .