Often customer-oriented, and it's our ultimate target to become not only probably reputable, trustable and honest provider, but also the partner for our customers for Membrane Filtration System , Uf System Water Treatment , Membrane Filtration Materials , As an expert specialized within this field, we've been committed to solving any problem of high temperature protection for users.
Factory wholesale Replacement Filter - UF Membrane Module 9 inch PVDF Ultrafiltration Membrane Module UFf2860 Replacing Project – Bangmo Detail:
Applications
Drinking treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service?conditions of different water sources:
Ingredient |
Effect |
SS, Particles?> 1μm |
Removal Rate?≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
>?4 log |
Turbidity |
< 1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 25NTU.
Product Parameters
![product-description1](https://ecdn6.globalso.com/upload/p/2605/source/2024-10/670cd4a703fce37883.jpg)
Technical Parameters
Filtering?Type |
Outside-in |
Membrane?Material |
Modified?PVDF |
MWCO |
200K Dalton |
Membrane?Area |
52m2 |
Membrane?ID/OD |
0.8mm/1.3mm |
Dimensions |
Φ225mm* 1860mm |
Connector?Size |
DN50 Clamping; Air?Inlet?– 10mm?air?pipe |
Application Data
Pure?Water?Flux |
8,000L/H?(0.15MPa, 25C) |
Designed?Flux |
40-120L/m2.hr?(0.15MPa, 25C) |
Suggested?Working?Pressure |
≤ 0.2MPa |
Maximum?Transmembrane?Pressure |
0.15MPa |
Maximum?Backwashing?Pressure |
0.15MPa |
Air?Washing?Volume |
0.1-0.15N m3/m2 .hr |
Air?Washing?Pressure |
≤ 0.1MPa |
Maximum?Working?Temperature |
45C |
PH?Range |
Working: 4-10; Washing: 2-12 |
Operating?Mode |
Cross?Flow?or Dead End |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused?by large particles in raw water.
Turbidity |
≤ 25NTU |
Oil?&?Grease |
≤?2mg/L |
SS |
≤ 20mg/L |
Total?Iron |
≤?1mg/L |
Continuous?Residual?Chlorine |
≤?5ppm |
COD |
Suggested?≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Backwashing?Flow?Rate |
100-150L/m2.hr |
Backwashing?Frequency |
Every?30-60min. |
Backwashing?Duration |
30-60s |
CEB?Frequency |
0-4?times per day |
CEB?Duration |
5-10min. |
CIP?Frequency |
Every 1-3 months |
Washing?Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic?Pollution?Washing |
0.2%?Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic?Pollution?Washing |
1-2% Citric?Acid/0.2% Hydrochloric?Acid |
Component Material
Component |
Material |
Membrane |
Modified?PVDF |
Sealing |
Epoxy?Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
To meet the customers' over-expected pleasure , we have now our solid crew to supply our great all round assistance which includes marketing, sales, planning, production, high quality controlling, packing, warehousing and logistics for Factory wholesale Replacement Filter - UF Membrane Module 9 inch PVDF Ultrafiltration Membrane Module UFf2860 Replacing Project – Bangmo , The product will supply to all over the world, such as: Bahrain, Karachi, San Francisco, All the employees in factory, store, and office are struggling for one common goal to provide better quality and service. Real business is to get win-win situation. We would like to provide more support for customers. Welcome all nice buyers to communicate details of our products with us!