We have advanced equipment. Our products are exported to the USA, the UK and so on, enjoying a good reputation among customers for Filtration Filter , Membrane Separation In Food Processing , Membrane Module , For more info, be sure to call us as shortly as possible!
factory Outlets for Ultrafiltration Systems Water Treatment - UF Membrane Module 10 inch PVC Ultrafiltration Membrane Module UFc250B River Water Treatment – Bangmo Detail:
Applications
Production of mineral water, mountain spring water and other sterile liquid.
Drinking treatment of tap water, surface water, well water, river water, etc.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service?conditions of different water sources:
Ingredient |
Effect |
SS, Particles?> 1μm |
Removal Rate?≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
>?4 log |
Turbidity |
< 0.1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 15NTU.
Product Parameters
Technical Parameters
Filtering?Type |
Inside-out |
Membrane?Material |
Modified?PVC |
MWCO |
100K Dalton |
Membrane?Area |
48m2 |
Membrane?ID/OD |
1.0mm/1.8mm |
Dimensions |
Φ250mm*1710mm |
Connector?Size |
DN50 Clamping |
Application Data
Pure?Water?Flux |
12,000L/H?(0.15MPa, 25C) |
Designed?Flux |
35-100L/m2.hr?(0.15MPa, 25C) |
Suggested?Working?Pressure |
≤ 0.2MPa |
Maximum?Transmembrane?Pressure |
0.2MPa |
Maximum?Working?Temperature |
45°C |
PH?Range |
Working: 4-10; Washing: 2-12 |
Operating?Mode |
Cross-flow?or?Dead-end |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused?by large particles in raw water.
Turbidity |
≤ 15NTU |
Oil?&?Grease |
≤?2mg/L |
SS |
≤ 20mg/L |
Total?Iron |
≤?1mg/L |
Continuous?Residual?Chlorine |
≤?5ppm |
COD |
Suggested?≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Maximum?Backwashing?Pressure |
0.2MPa |
Backwashing?Flow?Rate |
100-150L/m2.hr |
Backwashing?Frequency |
Every?30-60min. |
Backwashing?Duration |
30-60s |
CEB?Frequency |
0-4?times per day |
CEB?Duration |
5-10min. |
CIP?Frequency |
Every 1-3 months |
Washing?Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic?Pollution?Washing |
0.2%?Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic?Pollution?Washing |
1-2% Citric?Acid/0.2% Hydrochloric?Acid |
Component Material
Component |
Material |
Membrane |
Modified?PVC |
Sealing |
Epoxy?Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
We normally follow the basic principle Quality Initial, Prestige Supreme. We've been fully committed to offering our consumers with competitively priced good quality merchandise, prompt delivery and professional support for factory Outlets for Ultrafiltration Systems Water Treatment - UF Membrane Module 10 inch PVC Ultrafiltration Membrane Module UFc250B River Water Treatment – Bangmo , The product will supply to all over the world, such as: Paris, Sweden, Angola, To meet the requirements of individual customers for each bit more perfect service and stable quality products. We warmly welcome customers around the world to visit us, with our multi-faceted cooperation, and jointly develop new markets, create a brilliant future!